Horizontal screw biological centrifuge safety precautions

The horizontal screw centrifuge (referred to as the centrifuge for short) is a high-speed rotating machine that requires careful handling and strict adherence to safety protocols. Its components are manufactured with precision and carefully balanced to ensure smooth and safe operation. To guarantee optimal performance and prevent accidents, the following guidelines must be strictly followed: 1. All electrical systems of the centrifuge must be installed and grounded in accordance with local electrical codes and regulations. 2. The motor and control system should not be operated in areas where flammable or explosive materials are present until all safety devices are properly installed and functional. 3. If the centrifuge produces excessive noise or unusual sounds, it should be immediately stopped and inspected before resuming operation. 4. Never operate the centrifuge beyond its maximum rated speed, material specific gravity, operating pressure, or temperature limits. 5. If any damage such as cracks, rust, holes, or grooves are found on the drum, motor, or support structures, do not start the machine. 6. The centrifuge must not be operated without the protective cover or other necessary safety guards in place. 7. Before starting the motor, ensure that all mechanical parts are functioning correctly and there are no obstructions. 8. Keep rags, loose clothing, and body parts away from the rotating components to avoid entanglement or injury. 9. Regularly test and maintain all automatic shutdown systems and monitoring equipment to ensure they are working properly. 10. Inspect the foundation of the centrifuge and motor, as well as the tightness of bolts on supports, covers, and pipe connections on a regular basis. 11. Follow the manufacturer’s recommendations for lubrication schedules and use the correct type of lubricant. 12. Do not open the hood or perform any maintenance until the centrifuge has completely stopped and the power supply is disconnected. 13. Always follow the recommended procedures for assembly, disassembly, operation, and maintenance to ensure safe and efficient use. These precautions are essential for both the longevity of the equipment and the safety of the operators. It is important to train personnel thoroughly and ensure that all safety measures are strictly enforced. Keywords: horizontal screw biological centrifuge Source: http:// Submitted by: http://news.chinawj.com.cn

LED Flexible Rope Light

Led Flexible Rope Light,Led Neon Flex Rope Light,Silicone Led Rope Light,24V Waterproof Rope Light

Tianjin Jinji Optoelectronic Technology Co., Ltd. , https://www.tjjjgd.com

Posted on